IFM | Sensor Inductive Type IN0077  8,800
Description
Inductive sensor IN0077 IN-2002-BBOA

Product characteristics

Output functionnormally closed
Sensing range [mm]2
Housingrectangular
Dimensions [mm]40 x 12 x 26

Electrical data

Operating voltage [V]20…250 AC/DC
Protection classII
Reverse polarity protectionyes

Outputs

Output functionnormally closed
Max. voltage drop switching output DC [V]6
Max. voltage drop switching output AC [V]6.7
Minimum load current [mA]5
Max. leakage current [mA]2.0 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC)
Permanent current rating of switching output AC [mA]250; (350 (…50 °C))
Permanent current rating of switching output DC [mA]100
Short-time current rating of switching output [mA]2200; (50 ms / 1 Hz)
Switching frequency AC [Hz]25
Switching frequency DC [Hz]50
Short-circuit proofno
Overload protectionno

Detection zone

Sensing range [mm]2
Real sensing range Sr [mm]2 ± 10 %
Operating distance [mm]0…1.6

Accuracy / deviations

Correction factorsteel: 1 / stainless steel: 0.7 / brass: 0.25 / aluminium: 0.2 / copper: 0.05
Hysteresis [% of Sr]1…20
Switch point drift [% of Sr]-10…10

Operating conditions

Ambient temperature [°C]-25…80
ProtectionIP 67

Tests / approvals

EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated3 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted3 V
EN 55011 emissionclass B
MTTF [years]612

Mechanical data

Weight [g]104.7
Housingrectangular
Mountingflush mountable
Dimensions [mm]40 x 12 x 26
MaterialsPBT

Displays / operating elements

Display
switching status1 x LED, yellow

Electrical connection

Required protectionminiature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting

Remarks

Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity1 pcs.

Electrical connection

ConnectionCable: 2 m, PVC; 2 x 0.5 mm²
Additional information
delivery

Local Pickup