Inductive sensor NBN40-L1-E2-V1
General specifications | |
|---|---|
| Switching function | Normally open (NO) |
| Output type | PNP |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 … 32.4 mm |
| Actual operating distance | 36 … 44 mm |
| Reduction factor r Al | 0.33 |
| Reduction factor r Cu | 0.31 |
| Reduction factor r 304 | 0.74 |
| Reduction factor r Brass | 0.38 |
| Output type | 3-wire |
Nominal ratings | |
| Operating voltage | 10 … 30 V DC |
| Switching frequency | 0 … 180 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | ≤ 2 V |
| Operating current | 0 … 200 mA |
| Off-state current | 0 … 0.5 mA |
| No-load supply current | ≤ 20 mA |
| Time delay before availability | 80 ms |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
Functional safety related parameters | |
| MTTF d | 1510 a |
| Mission Time (T M) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives | |
| Standard conformity | |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates | |
| Protection class | II |
| Rated insulation voltage | 253 V |
| Rated impulse withstand voltage | 4000 V |
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions | |
| Ambient temperature | -25 … 85 °C (-13 … 185 °F) |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |
Mechanical specifications | |
| Connection type | Connector plug M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Degree of protection | IP68 / IP69K |
| Cable | |
| Cable diameter | 3.3 mm ± 0.15 mm |
| Mass | 130 g |
Dimensions | |
| Height | 40 mm |
| Width | 40 mm |
| Length | 67 mm |