Relpol Plug In Power Relay, 14 Pin ( R4N )  1,800
Description
R4N Series Plug In Power Relays for general applications

All relays are designed for mounting in plug-in sockets with WTL features as standard (W – mechanical indicator + T – lockable front test button)

• Compact size
• Relays of general application
• Cadmium – free contacts
• AC and DC coils
• For plug-in sockets, 35 mm rail mount or on panel mounting *
• WT (mechanical indicator + lockable front test button) – standard features of relays for plug-in sockets.

Relays may be provided with the test buttons (no latching) and plugs 

Induspare
Induspare
Induspare

Specifications

Number and type of contacts4 CO
Contact materialAgNi, AgNi/Au flash gold plating, AgNi/Au hard gold plating
Rated / max. switching voltage AC250 V / 250 V
Min. switching voltage

10 V AgNi, 10 V AgNi/Au flash gold plating

5 V AgNi/Au hard gold plating

Rated load (capacity) AC1 AC15 DC1

DC13

7 A / 230 V AC (VDE) 6 A / 250 V AC

1,5 A / 120 V 0,75 A / 240 V (C300)

6 A / 24 V DC (see Fig. 3)

0,22 A / 120 V 0,1 A / 250 V ( R300)

Motor load acc. to UL 508

AC3 acc. to IEC 60947-4-1

1/3 HP 240 V AC, 3,6 FLA, single-phase motor

0,125 kW 240 V AC, single-phase motor

Min. switching current5 mA
Max. make current12 A
Rated current7 A
Max. breaking capacity AC11 500 VA
Min. breaking capacity

0,3 W AgNi, 0,3 W AgNi/Au flash gold plating

0,1 W AgNi/Au hard gold plating

Contact resistance≤ 100 mΩ

Max. operating frequency • at rated load AC1

  • no load

1 200 cycles/hour

18 000 cycles/hour

Coil data 

Rated voltage 50/60 Hz AC

DC

6, 12, 24, 42, 48, 60, 80, 110, 115, 120, 127, 220, 230, 240 V

5, 6, 12, 24, 48, 60, 80, 110, 125, 220 V

Must release voltageAC: ≥ 0,2 U n DC: ≥ 0,1 U n
Operating range of supply voltagesee Tables 1, 2 and Fig. 4, 5

Rated power consumption AC

DC

50 Hz: 1,6 VA 60 Hz: 1,3 VA

0,9 W

Insulation according to EN 60664-1 
Insulation rated voltage250 V AC
Rated surge voltage2 500 V 1,2 / 50 µs
Overvoltage categoryII
Insulation pollution degree2

Dielectric strength • between coil and contacts

  • contact clearance
  • pole – pole

2 500 V AC type of insulation: basic

1 500 V AC type of clearance: micro-disconnection

2 000 V AC type of insulation: basic

Contact – coil distance • clearance

  • creepage

≥ 1,6 mm

≥ 3,2 mm

General data 
Operating / release time (typical values)AC: 10 ms / 8 ms DC: 13 ms / 5 ms

Electrical life • resistive AC1

  • cosφ

> 5 x 10 4 7 A, 230 V AC (VDE)

> 10 5 6 A, 250 V AC

see Fig. 2

Mechanical life (cycles)> 2 x 10 7
Dimensions (L x W x H)27,4 x 21 x 35,5 mm
Weight35 g

Ambient temperature • storage

(non-condensation and/or icing) • operating

-40…+85 oC

coil AC: -40…+55 oC coil DC: -40…+70 oC

Cover protection categoryIP 40 EN 60529
Environmental protectionRTI EN 61810-1
Shock resistance (NO/NC)10 g / 5 g
Vibration resistance5 g 10…150 Hz
Additional information
delivery

Local Pickup

Models

R4N-2014-23-1024-WTL, R4N-2014-23-1125-WTL, R4N-2014-23-5012-WTL, R4N-2014-23-5110-WTL 

Coil Type

24VDC, 125VDC, 12VAC, 110VAC