BYD3M-TDT
-
- Sensing type : Through-beam type
- Sensing distance : 3m
- Sensing target : Opaque material of min. Ø6mm
- Light source : Infrared LED
- Response time : Max. 1ms
Sku: BYD3M-TDT-PAutonics Sensor Through Beam Type BYD3M-TDT-P
₨ 10,000 -
-
-
-
Features
- Improved the noise immunity with dedicated IC
- Built-in reverse polarity protection circuit (DC 3-wire type)
- Built-in surge protection circuit
- Built-in over-current protection circuit (DC type)
- Long life cycle and high reliability, and simple operation
- IP67 protection structure (IEC standard)
- Replaceable for micro switches and limit switches
Sku: PR18-5ACAutonics Sensor Inductive Type PR18-5AC
₨ 9,500 -
-
TCN4H-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
Sku: TCN4H-24RAutonics Temperature Controller TCN4H-24R
₨ 50,000 -
TCN4L-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
Sku: TCN4L-24RAutonics Temperature Controller TCN4L-24R
₨ 50,000 -
TCN4M-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
Sku: TCN4M-24RAutonics Temperature Controller TCN4M-24R
₨ 50,000 -
TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
Sku: TCN4S-24RAutonics Temperature Controller TCN4S-24R
₨ 50,000 -
TK4S-B4CR
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω Analog: 0-100mV, 0-5V, 1-5V, 0-10V 0-20mA, 4-20mA
- Sampling cycle : 50ms
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC ) [ON/OFF]
- Option output : Alarm 1/2, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz
- Protection structure : IP65(front panel)
Sku: TK4S-B4CRAutonics Temperature Controller TK4S-B4CR
₨ 50,000 -
-
Hot
- Convenient DIN rail mounting type
- Response time: max. 1 ms
- Enables to adjust sensitivity with high accuracy by coarse and fine adjuster
- Selectable Light ON/Dark ON operation mode by control wire
- Reverse power protection and output short overcurrent protection circuit
- Adjustable length with free cut type fiber optic unit
Sensor: optical fiber amplifier; PNP; Connection: lead 2m; 200mASku: BF3RX-PAutonics Sensor Optical Fiber Amplifier BF3RX-P
₨ 30,000 -
-
A Reactive Power Regulator (RPR) is a device used in electrical power systems to manage and control reactive power. Reactive power is the portion of power in an AC circuit that doesn't perform any useful work but is necessary for the operation of devices like motors and transformers. The main purpose of a Reactive Power Regulator is to regulate and optimize the reactive power flow in the power system. This helps in maintaining voltage levels within acceptable limits, improving power factor, and ensuring the efficient and stable operation of the electrical grid. Key functions of a Reactive Power Regulator may include:
- Voltage Regulation: Reactive power regulators can adjust the voltage levels to keep them within specified limits. This is crucial for maintaining the stability and reliability of the power system.
- Power Factor Correction: Power factor is a measure of how effectively electrical power is converted into useful work output. Reactive power regulators can improve the power factor by adjusting the flow of reactive power.
- Stability Enhancement: By managing reactive power flow, these regulators contribute to the overall stability of the power system, preventing voltage sags or surges.
- Optimizing Transmission Efficiency: Reactive power control can help in minimizing power losses in transmission lines, thereby enhancing the overall efficiency of the power grid.
Sku: BLR-CX 12RBeluk | Reactive Power Regulator BLR-CX, 12 steps (relay outputs)
₨ 64,000 -
A Reactive Power Regulator (RPR) is a device used in electrical power systems to manage and control reactive power. Reactive power is the portion of power in an AC circuit that doesn't perform any useful work but is necessary for the operation of devices like motors and transformers. The main purpose of a Reactive Power Regulator is to regulate and optimize the reactive power flow in the power system. This helps in maintaining voltage levels within acceptable limits, improving power factor, and ensuring the efficient and stable operation of the electrical grid. Key functions of a Reactive Power Regulator may include:
- Voltage Regulation: Reactive power regulators can adjust the voltage levels to keep them within specified limits. This is crucial for maintaining the stability and reliability of the power system.
- Power Factor Correction: Power factor is a measure of how effectively electrical power is converted into useful work output. Reactive power regulators can improve the power factor by adjusting the flow of reactive power.
- Stability Enhancement: By managing reactive power flow, these regulators contribute to the overall stability of the power system, preventing voltage sags or surges.
- Optimizing Transmission Efficiency: Reactive power control can help in minimizing power losses in transmission lines, thereby enhancing the overall efficiency of the power grid.
Sku: BLR-CX 06RBeluk | Reactive Power Regulator BLR-CX, 6 steps (relay outputs)
₨ 48,000 -
Description:
Pre-assembled connecting cables with M 12 female connector (M 12x1 female thread according to DIN EN 61076-2-101, A-coded, 5-pole) and on the other side, loose cable ends or M 12 male connector (M 12x1 male thread according to DIN EN 61076-2-101, A-coded, 5-pole) Temperature range: -25°C to +90°C Voltage: max. 60 V AC/DC, max. 4 A Protection class: IP 67 Cable: PUR cable, 4 or 5 x 0.34 mm² (only for static applications) Cable layout: Pin 1 - brown, Pin 2 - white, Pin 3 - blue, Pin 4 - black, Pin 5 - grey (only present if 5-core)Cable with M12 coupling, 4 Pin , 3 m, L Type , Black & Gray
₨ 1,200