Inductive sensor NBB10-30GM40-Z0-V1
General specifications | ||
|---|---|---|
| Switching function | Normally open (NO) | |
| Output type | Two-wire | |
| Rated operating distance | 10 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 … 8.1 mm | |
| Actual operating distance | 9 … 11 mm typ. | |
| Reduction factor rAl | 0.3 | |
| Reduction factor rCu | 0.25 | |
| Reduction factor r304 | 0.7 | |
| Output type | 2-wire | |
Nominal ratings | ||
| Operating voltage | 5 … 60 V | |
| Switching frequency | 0 … 150 Hz | |
| Hysteresis | 1 … 10 typ. 5 % | |
| Reverse polarity protection | reverse polarity tolerant | |
| Short-circuit protection | pulsing | |
| Voltage drop | ≤ 5 V | |
| Operating current | 2 … 100 mA | |
| Lowest operating current | 2 mA | |
| Off-state current | 0 … 0.5 mA typ. | |
| Time delay before availability | ≤ | |
| Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
| MTTFd | 1710 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
| Standard conformity | Â | |
| Â | Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
Mechanical specifications | ||
| Connection type | Connector plug M12 x 1 , 4-pin | |
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Dimensions | Â | |
| Â | Length | 40 mm |
| Â | Diameter | 30 mm |