Inductive sensor NBN40-L1-E2-V1
General specifications | |
---|---|
Switching function | Normally open (NO) |
Output type | PNP |
Rated operating distance | 40 mm |
Installation | non-flush |
Output polarity | DC |
Assured operating distance | 0 … 32.4 mm |
Actual operating distance | 36 … 44 mm |
Reduction factor r Al | 0.33 |
Reduction factor r Cu | 0.31 |
Reduction factor r 304 | 0.74 |
Reduction factor r Brass | 0.38 |
Output type | 3-wire |
Nominal ratings | |
Operating voltage | 10 … 30 V DC |
Switching frequency | 0 … 180 Hz |
Hysteresis | typ. 5 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ≤ 2 V |
Operating current | 0 … 200 mA |
Off-state current | 0 … 0.5 mA |
No-load supply current | ≤ 20 mA |
Time delay before availability | 80 ms |
Operating voltage indicator | LED, green |
Switching state indicator | LED, yellow |
Functional safety related parameters | |
MTTF d | 1510 a |
Mission Time (T M) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives | |
Standard conformity | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates | |
Protection class | II |
Rated insulation voltage | 253 V |
Rated impulse withstand voltage | 4000 V |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions | |
Ambient temperature | -25 … 85 °C (-13 … 185 °F) |
Storage temperature | -40 … 85 °C (-40 … 185 °F) |
Mechanical specifications | |
Connection type | Connector plug M12 x 1 , 4-pin |
Housing material | PA |
Sensing face | PA |
Degree of protection | IP68 / IP69K |
Cable | |
Cable diameter | 3.3 mm ± 0.15 mm |
Mass | 130 g |
Dimensions | |
Height | 40 mm |
Width | 40 mm |
Length | 67 mm |